    The label that shows information says:
    Compressor Oil 3GS
    Viscosity 150 SUS (ISO32)
    SUNISO (L318)
    Mixture # MX1042
    Installation 8/2006
    Another label says
    Part No. AF0343-011
    Model No. CC2402-1
    Power Input 115VAC 60 HZ
    Serial No. 060807 KA
    About this X-Cooler II:
    This was purchased at an auction with a whole lot of other items.
    When this was powered on, the unit did not cool.  I am sure the compressor was running.
    I did contact Ortec and they told me the following:
    Unfortunately, the entire X-Cooler product line (X-Cooler I, II, III) has been obsoleted and is no longer supported. You can attempt to reach out to the company who used to build these for ORTEC to see if they can be of help.
    And I did look up MMR and the web site is no longer registered to them, and I am guessing they went out of business.
    This is in it's own Plastic Shipping Crate.  The size is  40" x 26" x 27" and it weighs 110 Pounds.  It was shipped via UPS at one time and I'm guessing the price was up there.
    Since it didn't cool and I didn't get any more information that would help me get this cooling, so it is sold as is.
    You are welcome to pick this up in Natick, MA
    Check out my
    other items
    where I have a lot of other scientific equipment and accessories for sale.
    More Information:
    Replace Liquid Nitrogen with the New X-COOLER II

    More Powerful than Ever

    No Limit to Detector Size

    For HPGe Detectors within a Wide Range of Gamma Spectroscopy Applications

    Compatible with All ORTEC HPGe Detector Types

    Lightweight and Compact Design

    Low Power Operation (less than 400 W)

    Field Replaceable: Retrofits to Existing Detectors and is Easily Maintained

    Cool HPGe Detectors Anywhere There’s Electricity!

    No Dewar Filling Operations

    No LN
    2
    Safety Hazard

    No Bulky Storage Tanks or Unwieldy Plumbing Systems

    A Truly Economical Alternative to Liquid Nitrogen
    Introducing X-COOLER II
    Now There is No Limit to the Size of
    Detector that can be Cooled by
    Mechanical Cooling. . .
    There is virtually no limit to the HPGe laboratory
    applications that can be optimized by mechanical cooling
    with the new X-COOLER II. This exciting new product
    extends the capability of mechanical cooling to any size
    detector!
    That’s right. . . any size detector!
    The use of LN
    2
    has truly become a thing of the past!
    . . . and you’ll save money, time, and operating costs!
    The annual cost of running an X-COOLER II can actually
    be less than that of an LN
    2
    -cooled detector.
    A Variety of Detector Options
    X-COOLER II is designed to work with any ORTEC
    detector available in PopTop configurations. Degradation
    of resolution performance is guaranteed to be less than
    10% for energies less than 500 keV, and no degradation
    will be observed above 500 keV.
    Light on
    X-COOLER II is not only inexpensive to purchase and
    operate, but it is smaller and lighter than other devices of
    this type. The compact design boasts a footprint of less
    than one square foot (or 930 cm
    2
    ), stands 11” (28 cm)
    tall, and weighs less than 36 pounds (16.4 kg). This
    compares very favorably to the previous generation of
    mechanical coolers.
    Field Replaceable
    Reliability and ease of service are essential to any
    mechanical cooling system for HPGe detectors.
    X-COOLER II systems employ the ORTEC patented
    1
    PopTop™ detector capsule technology. While the design
    life of the X-COOLER II is greater than five years, there is
    always the possibility of failure of any mechanical system.
    Because of the unique PopTop design of ORTEC
    detectors, an X-COOLER II can be replaced in the field,
    without special tools or procedures. After the detector has
    returned to room temperature, a new X-COOLER II can
    be installed in less than 10 minutes. The detector does
    not have to be returned to the factory to replace a faulty
    mechanical cooling system.
    Retrofittable
    The X-COOLER II can be retrofit in the field to existing
    PopTop detectors. Simply warm the existing detector,
    unscrew the capsule from the LN
    2
    cryostat, and couple
    onto the new X-COOLER II.
    You’ll be up and running in no time!
    Proven Technology
    Traditional mechanical coolers fail because oil from the
    compressor mixes with the refrigerant, migrating to the
    heat exchanger and clogging it, thus causing the detector
    to warm up. The X-COOLER II's patented design cleans
    the oil out of the refrigerant continuously. Similar coolers
    using this design have logged over 38,000 hours (more
    than 4-1/4 years) of operation without failure... and still
    going.
    Specifications
    *
    Resolution:
    Detector specifications are warranted to
    no
    degradation above 500 keV and less than 10%
    degradation of the warranted and published LN
    2
    specifications at less than 500 keV.
    Mechanical:
    Dimensions:
    Compressor: 12.5” W x 12.5” D x 11” H
    (31.8 cm x 31.8 cm x 28 cm)
    Cold Head Length with Detector Capsule
    Standard: 23.25” (59 cm)
    Oversize: 24.5” (62.3 cm)
    Ultra: 25.5” (64.8 cm)
    Weight:
    Compressor: 36 lbs. (16.4 kg)
    Cold Head: 11 lbs. (5 kg) not including capsule
    Noise:
    Less than 70 dB at 1 meter
    Input Power:
    110–120 V ac, 57–63 Hz or
    220–240 V ac, 47–53 Hz (input power must be
    selected by choosing the appropriate model number,
    see ordering information)
    Power Consumption: <
    500 W during initial cool
    down. <400 W during normal operation.
    Connector Hose:
    10 ft. gas hose connected
    between compressor box and cold head assembly is
    included. Longer lengths available on special request.
    Contact the factory for more information and pricing
    on other hoses.
    Refrigerant:
    Mixed gas, CFC-free refrigerant.
    MSDS available on request.
    CE Approved
    Please use the shipping calculator to determine shipping.
    Check out my
    other items
    !
    If you receive your item and it is not to your 100 Percent Satisfaction, please contact us before leaving feedback.
    I strive to make sure every transaction is a positive one!
    IF you have a problem with my item, I would like you to use the "Contact Seller" link in the listing, or call me. Please don't open a case. Cases count against me even if they are resolved.
    I stand behind my items and will work out any problems that you may have with an item.
    So please contact me if you have a problem with an item I have sold you and don't use the eBay Case as a means of communication.
    International Buyers, Please Note: Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying. These charges are normally collected by the delivering freight (shipping) company or when you pick the item up do not confuse them for additional shipping charges. We do not mark merchandise values below value or mark items as "gifts". US and International government regulations prohibit such behavior.
    Powered by SixBit's eCommerce Solution